Open Source Robotics

A curated collection of high-quality open source robotics projects, tools, and software to propel the robotics community forward.

OpenTac

Open flex-PCB tactile skins that sense normal and shear force, made for any robot surface

License

  • code: MIT
  • hardware: CERN-OHL-P 2.0 (permissive)
  • documentation and media: CC BY 4.0

Split licensing: code MIT, hardware designs CERN-OHL-P-2.0, documentation and media CC BY 4.0. Some third-party robot meshes in examples/stl/ keep their own licences, some non-commercial (see examples/stl/end_effectors/SOURCES.md). Checked 2026-10-23.

Overview

OpenTac is an open tactile sensor system from Johns Hopkins University and MIT that you design to fit a particular robot surface. Each sensor is a flexible PCB with a grid of electrodes (taxels), a piezoresistive film on top, and a 3D-printed TPU lid with one soft bump over every 2×2 group of taxels. The sum of the four readings under a bump gives normal force and their differences give shear. OpenTac-CAD turns a drawn outline, a DXF or a surface of an STL part into a manufacturable sensor: Gerbers for the flex PCB, the printed case, a paper fit-check template and a manifest describing the sensor. It runs locally or in the browser. Two open readout boards read the sensor over USB and carry an IMU. The repository also holds the firmware, a Python package for reading, viewing and simulating sensors, and tools for transferring data between sensor designs. It is described in the OpenTac paper.

A resistive tactile skin normally gives one number per taxel: how hard it is pressed. OpenTac adds shear with a printed overlay. The lid generated with the board places a soft TPU bump over each 2×2 group of taxels, and the cross-shaped base of each bump seats in the gaps between the electrodes, so the bump centres itself without a jig. Pressing straight down loads the four taxels evenly; a sideways force tilts the bump and shifts the load to one side. On a bumped 4×4 patch the authors report R² of 0.95, 0.93 and 0.96 for Fx, Fy and Fz against an OptoForce reference.

The design tool is what makes it general. OpenTac-CAD lays out the taxel grid inside the target outline, routes the rows and columns, adds the connector tail with its stiffener, runs a design-rule check and exports the KiCad board, Gerbers, printed case, a 1:1 PDF for checking the fit on the real part and DXF or fold-template files for cutting the piezoresistive layer. The authors designed and fabricated 31 sensors with it, up to 1,024 taxels each, and all passed the design-rule check and worked. On five robot surfaces it covered 75–93% of the target area in 0.7–2.6 s. The repository also ships a skill that lets a coding agent design sensors from a short request.

The readout boards are open hardware too. The 60-pin board reads up to 30×30 taxels and has 16 gain settings. The 30-pin pair is two stacked boards for up to 15×15 taxels in tight spaces such as fingers, and several of them can be daisy-chained over I2C behind a Teensy 4.0. Both use an STM32G431 and drive unselected rows to ground to suppress ghosting between pressed taxels. Both stream an LSM6DSV16BX IMU's vibration and orientation alongside the tactile frames, and both show up as a USB serial port that also flashes their firmware. The same sensor manifest configures the board, OpenTac-Sim (a quick foam model, or a MuJoCo model for skins with the bump sheet), OpenTac-Transfer (mapping calibrated force data from one sensor layout to another) and OpenTac-Xampling. Xampling is an adaptive readout: on a 1,024-taxel skin it gives 1,286 partial frames per second of 16 taxels each, against 67 full raster frames.

The paper's demonstrations include contact-rich insertion with ACT policies on an SO-101 arm and a bimanual YAM setup, where shear data mattered, and slip prevention when holding a cup on a Dexmate Vega-1 Pro.

Why it matters

Tactile sensing is one of the obvious gaps in open robot hardware. Most open sensors are a fixed shape, such as the camera-based fingertip of ShadowTac or the OSMO tactile glove, and fitting one to a different gripper or hand means redesigning it by hand. OpenTac makes the shape an input. It is published whole, from design tool and board files to firmware, simulator and ordering guides, under MIT, CERN-OHL-P and CC BY licences. That lets a lab put a normal-and-shear skin on the gripper it already uses by ordering two kinds of PCB and printing a TPU case, rather than building or buying a sensor around someone else's geometry.

Problem it solves

Covering a robot's fingers, jaws or body with touch sensing usually means either buying a fixed-shape commercial sensor or designing a custom flexible circuit, its wiring and its readout by hand for each surface. Most low-cost resistive skins also sense only pressure, not the shear that tells a robot something is slipping. OpenTac generates the circuit, case and cutting templates for an arbitrary surface automatically, adds shear sensing with a printed bump layer, and provides open readout electronics and software to use the result.

Key takeaways

  • OpenTac-CAD turns an outline, DXF or STL surface into a flex-PCB tactile sensor, a printed case and a manifest in seconds
  • A TPU lid with one bump per 2×2 taxels gives shear as well as normal force; the paper reports R² of 0.93–0.96 per axis on a bumped 4×4 patch
  • Two open readout boards (60-pin up to 30×30 taxels, 30-pin pair up to 15×15) with STM32G431, IMU and USB, ordered fully assembled from JLCPCB
  • 31 sensors were designed with the tool and fabricated for the paper; all worked, with up to 1,024 taxels each
  • Python package for reading, live viewing, simulation and cross-sensor transfer; adaptive readout reaches 1,286 partial frames per second on a 1,024-taxel skin
  • Code MIT, hardware CERN-OHL-P-2.0, documentation CC BY 4.0

Who it is for

  • Researchers adding touch and slip sensing to grippers, hands and arms
  • Labs training contact-rich manipulation policies that want tactile and shear inputs
  • Builders of open robots, such as SO-101 or LEAP Hand owners, who want a skin for their own geometry
  • Engineers prototyping large-area or oddly shaped robot skins

Limitations

  • Two printed circuit orders are needed: a flex PCB with gold fingers and a polyimide stiffener, and a fully assembled readout board, each typically days to weeks with shipping
  • Readout boards are ordered with JLCPCB assembly; the upstream example quote on 16 October 2026 was $378.26 for five 60-pin boards before shipping, mostly components
  • Response depends on the piezoresistive material and taxel geometry: at the default gain the range is about 0.1–10 N, and in a 10-hour pressing test readings rose for the first three hours before levelling off
  • Shear needs the soft TPU bump lid (Shore 85–95A); a rigid print reads normal force only
  • Released 19 October 2026; young project, and some third-party robot meshes among the example STLs carry non-commercial licences

This website requires JavaScript to function properly. Please enable JavaScript to explore our collection of open source robotics projects.