Open Source Robotics

A curated collection of high-quality open source robotics projects, tools, and software to propel the robotics community forward.

Tendon-Driven Actuation

  • Also called: cable-driven actuation, tendon actuation
  • Category: Actuation & drivetrain › Transmission
  • Tags: actuation, transmission, robot-hands, soft-robotics, mechanism-design

Driving a robot's joints through cables or tendons pulled by remotely mounted actuators, so that motors can sit away from the moving links they control.

Definition

Tendon-driven actuation moves a joint by pulling on a cable, or tendon, that runs from an actuator to an attachment point beyond the joint. The tendon is routed over pulleys, through guide channels or inside a flexible sheath, as in a Bowden cable, so the motor can be placed in the palm, forearm or base rather than at the joint itself. The human hand works the same way: most of the muscles that move the fingers sit in the forearm and act through long tendons.

Tendons can only pull, not push. A joint that must be driven in both directions therefore needs either an antagonistic pair of tendons, one on each side, or a single tendon working against a return spring or elastic element. With pull-only tendons, independently controlling n joints requires at least n+1 tendons, and many designs use 2n, one antagonistic pair per joint. A common low-cost arrangement wraps both ends of a pair around one servo pulley, so turning the servo shortens one tendon and lengthens the other, bending the finger in one plane. Routing a tendon across several joints couples them, which can be used deliberately for underactuated grasping or must be compensated for when joints should move independently.

The main advantage is low mass and inertia in the moving links, which allows slim fingers, compact continuum and soft robots, and light wearable devices. The costs are friction along the routing, which grows with the total wrap angle and makes force at the joint differ from force at the motor; tendon stretch and creep, which add compliance and change calibration over time; the need for pretension so tendons do not go slack; and the wear and maintenance of cables. Control often has to estimate joint angles separately, because motor position alone does not give them reliably.

Why it matters

Tendons let designers move heavy actuators away from where space and weight are tight, which is why they appear in many dexterous hands, continuum robots and soft exosuits. Understanding their pull-only nature, friction and stretch explains much of the behavior, and many of the calibration problems, of these systems.

Key applications

  • Dexterous and anthropomorphic robot hands
  • Soft and compliant grippers and fingers
  • Continuum and surgical robots steered by multiple tendons
  • Soft exosuits and wearable assistive devices using Bowden cables
  • Lightweight arms that keep motors at the base to reduce moving inertia

In practice

A team builds a soft robotic finger for a care robot. Two nylon-coated tendons run through channels on opposite sides of a cast silicone finger and wrap in opposite directions around a single hobby servo's pulley. Turning the servo one way shortens the front tendon and lets out the back one, curling the finger; turning it the other way straightens it. A second servo with its own pair bends the finger in the perpendicular plane. During testing the team finds that the finger lags the servo at small angles because of slack, so they add a tensioning screw and recalibrate the servo-to-curl mapping, and they replace a sharp channel exit that was fraying the tendon.

Common misconceptions

  • A single tendon can drive a joint both ways — tendons only pull, so bidirectional motion needs an antagonistic tendon or a return spring
  • Motor position gives joint position exactly — friction, slack and tendon stretch introduce errors that often need joint sensing or calibration
  • Tendon-driven and underactuated mean the same thing — tendons can drive fully actuated joints; underactuation arises only when fewer actuators than joints are used
  • Force at the motor equals force at the joint — friction along pulleys and sheaths can lose a significant share of the tension, depending on routing

Who should know this

  • Robot hand and gripper designers
  • Soft and continuum robotics engineers
  • Wearable robotics and exosuit developers
  • Makers building low-cost servo-driven fingers

Related technologies

  • Bowden Cable
  • Antagonistic Actuation
  • Capstan Drive
  • Continuum Robots
  • Soft Exosuits

Related terms

  • Underactuated Hand
  • Dexterous Manipulation
  • Soft Robotics
  • Exoskeleton
  • Servo Motor
  • Passive Compliance

Related projects

  • SOFA Framework: Real-time physics simulation framework for medical simulation and soft tissue modeling
  • wuji-mjlab: Train and deploy in-hand cube and pen-spinning policies on the Wuji Hand
  • Delta X Soft Gripper: Soft gripper for the Delta X robot: STL and STEP files, print settings and a build video
  • DexSuite: Simulation framework for dexterous manipulation: any task with any arm and hand

This website requires JavaScript to function properly. Please enable JavaScript to explore our collection of open source robotics projects.